SEA LEVEL STATION MONITORING FACILITY
IntroMapStation listsStation detailsServices & FAQGLOSSCatalog
[previous station] Station at GMT [next station]
[less details] [GTS message] [show data] [show on map] [monitor]
Station metadata
Code pada
Country Indonesia
Location Padang
Status Operational
Added to the system 2006-06-08 04:51:00
Local Contact Geospacial Agency of Indonesia ( Indonesia )
Other Contact University of Hawaii Sea Level Center ( USA )
GLOSS core ID 45   [goto handbook]
Long-term MSL data
Latitude -0.95
Longitude 100.3667
Connection GTS message
GTS message type SZID50
GTS station code 06510374
Transmit interval (min) 6
Transmit lag UTC (sec) 0
Ave. transmit delay (min) 2
Messages received (24h) 232
Messages expected (24h) 240
Sensor 1
Type of sensorprs (pressure)
Sampling rate (min)1
    GTS format
Units of measurem
First value4
Samples12
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h1428
Measurements expected1440
Performance ratio99%
Sensor 2
Type of sensorrad (radar)
Sampling rate (min)3
    GTS format
Units of measurem
First value19
Samples12
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h480
Measurements expected480
Performance ratio100%
Sensor 3
Type of sensorenc (float sensor with encoder)
Sampling rate (min)6
    GTS format
Units of measurem
First value34
Samples4
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h240
Measurements expected240
Performance ratio100%
Sensor 4
Type of sensorsw1 (1st switch)
Sampling rate (min)60
    GTS format
Units of measuremin
First value41
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h232
Measurements expected24
Performance ratio967%
Sensor 5
Type of sensorsw2 (2nd switch)
Sampling rate (min)60
    GTS format
Units of measuremin
First value45
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h232
Measurements expected24
Performance ratio967%
Sensor 6
Type of sensorbat (battery)
Sampling rate (min)6
    GTS format
Units of measureV
First value49
Samples1
Reversed orderno
    Performance statistics
Last data measured at2024-11-23 14:34:00
Last data received at2024-11-23 14:36:01
Measurements received in 24h232
Measurements expected240
Performance ratio97%
Period SignalsData

12h
day
7 days
30 days
prs (pressure)
rad (radar)
enc (float sensor with encoder)
Remove outliers
Remove spikes
Relative levels = signal - median over selected period
Absolute levels = as received
Offset signals = relative levels + offset
Show switch data
Show battery voltage
Tip:use left icons to zoom & scroll